ThermoSense: Occupancy Thermal Based Sensing for HVAC Control

Alex Beltran, Varick L. Erickson, Alberto E. Cerpa

Abstract

In order to achieve sustainability, steps must be taken to reduce energy consumption. In particular, heating, cooling, and ventilation systems, which account for 42% of the energy consumed by US buildings in 2010 [8], must be made more efficient. In this paper, we demonstrate ThermoSense, a new system for estimating occupancy. Using this system we are able to condition rooms based on usage. Rather than fully conditioning empty or partially filled spaces, we can control ventilation based on near real-time estimates of occupancy and temperature using conditioning schedules learned from occupant usage patterns. ThermoSense uses a novel multisensor node that utilizes a low-cost, low-power thermal sensor array along with a passive infrared sensor. By using a novel processing pipeline and sensor fusion, we show that our system is able measure occupancy with a RMSE of only ≈0.35 persons. By conditioning spaces based on occupancy, we show that we can save 25% energy annually while maintaining room temperature effectiveness.

Availability

PDF

Reference

Alex Beltran, Varick L. Erickson, Alberto E. Cerpa, "ThermoSense: Occupancy Thermal Based Sensing for HVAC Control," Proceedings of the Fifth ACM Workshop on Embedded Sensing Systems for Energy-Efficient Buildings (BuildSys 2013), pp. 11:1--11:8, ACM, Rome, Province of Rome, Italy, 2013.

Bibtex

@Conference{Beltran13a,
  author =       "Alex Beltran and Varick L. Erickson and Alberto E.
                 Cerpa",
  title =        "ThermoSense: Occupancy Thermal Based Sensing for
                 {HVAC} Control",
  booktitle =    "Proceedings of the Fifth ACM Workshop on Embedded
                 Sensing Systems for Energy-Efficient Buildings
                 (BuildSys 2013)",
  year =         "2013",
  pages =        "11:1--11:8",
  address =      "Rome, Province of Rome, Italy",
  publisher =    "ACM",
  ISBN =         "978-1-4503-2431-1",
  articleno =    "11",
  doi =          "10.1145/2528282.2528301",
  acmid =        "2528301",
  keywords =     "HVAC Control, Occupancy Sensing, Thermal Sensing",
  URL =          "http://www.andes.ucmerced.edu/papers/Beltran13a.pdf",
  accept =       "40",
}

Copyright

This paper is copyright © 2013 by its authors. Permission to make digital or hard copies of part or all of this work for personal use is granted without fee provided that copies are not made or distributed for profit or commercial purposes. New copies must bear this notice and the full citation on the first page. Abstracting with credit is permitted. To copy otherwise, to republish, to post on servers or to redistribute to lists, requires prior specific permission of the authors.